리눅스에서 하드정보(SMART) 보기

하드가 얼마나 오래 썼는지 종종 확인하는데 윈도우에는 CrystalDiskInfo 라는게 있어서 쉽게 볼수 있다. 리눅스에서도 방법이 있겠지 하고 검색해봄. 그리고 여기 정리함.

sudo apt install smartmontools

smartmontools 설치를 해줌.

smartctl 옵션 드라이브

이런식으로 명령을 주면 되는데 간단한 정보는 -i를 자세한 정보는 -a를 붙이면 된다.

linsoo@ubuntu:~$ sudo smartctl -i /dev/sda
smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.4.0-57-generic] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Western Digital Blue Mobile
Device Model:     WDC WD5000LPVX-22V0TT0
Serial Number:    
LU WWN Device Id: 
Firmware Version: 
User Capacity:    500,107,862,016 bytes [500 GB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    5400 rpm
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ACS-2 (minor revision not indicated)
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Fri Jan  6 10:11:27 2017 KST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

간단한 정보

linsoo@ubuntu:~$ sudo smartctl -a /dev/sda
smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.4.0-57-generic] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Western Digital Blue Mobile
Device Model:     WDC WD5000LPVX-22V0TT0
Serial Number:    
LU WWN Device Id: 
Firmware Version: 
User Capacity:    500,107,862,016 bytes [500 GB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    5400 rpm
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ACS-2 (minor revision not indicated)
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Fri Jan  6 10:13:32 2017 KST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (10260) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 117) minutes.
Conveyance self-test routine
recommended polling time:        (   5) minutes.
SCT capabilities:              (0x7035) SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   200   200   051    Pre-fail  Always       -       0
  3 Spin_Up_Time            0x0027   156   150   021    Pre-fail  Always       -       1200
  4 Start_Stop_Count        0x0032   088   088   000    Old_age   Always       -       12550
  5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x002e   200   200   000    Old_age   Always       -       0
  9 Power_On_Hours          0x0032   094   094   000    Old_age   Always       -       4410
 10 Spin_Retry_Count        0x0032   100   100   000    Old_age   Always       -       0
 11 Calibration_Retry_Count 0x0032   100   100   000    Old_age   Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       641
191 G-Sense_Error_Rate      0x0032   050   050   000    Old_age   Always       -       50
192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age   Always       -       101
193 Load_Cycle_Count        0x0032   192   192   000    Old_age   Always       -       26203
194 Temperature_Celsius     0x0022   108   089   000    Old_age   Always       -       35
196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always       -       0
197 Current_Pending_Sector  0x0032   200   200   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0030   100   253   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       -       0
200 Multi_Zone_Error_Rate   0x0008   100   253   000    Old_age   Offline      -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

자세한 정보
나는 주로 위에 Power_On_Hour를 확인하기 위해 사용함.

Odroid HC1은 위 옵션으로는 “알수없는 브릿지” 라고 하면서 안나오는데 아래와 같이 옵션을 주면 나온다.

sudo smartctl -x -d sat /dev/sda

Comments

“리눅스에서 하드정보(SMART) 보기” 에 하나의 답글

  1. 오드로이드는 저렇게 해야되는군요 감사합니다.

답글 남기기