하드가 얼마나 오래 썼는지 종종 확인하는데 윈도우에는 CrystalDiskInfo 라는게 있어서 쉽게 볼수 있다. 리눅스에서도 방법이 있겠지 하고 검색해봄. 그리고 여기 정리함.
sudo apt install smartmontools
smartmontools 설치를 해줌.
smartctl 옵션 드라이브
이런식으로 명령을 주면 되는데 간단한 정보는 -i를 자세한 정보는 -a를 붙이면 된다.
linsoo@ubuntu:~$ sudo smartctl -i /dev/sda smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.4.0-57-generic] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Blue Mobile Device Model: WDC WD5000LPVX-22V0TT0 Serial Number: LU WWN Device Id: Firmware Version: User Capacity: 500,107,862,016 bytes [500 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Fri Jan 6 10:11:27 2017 KST SMART support is: Available - device has SMART capability. SMART support is: Enabled
간단한 정보
linsoo@ubuntu:~$ sudo smartctl -a /dev/sda smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.4.0-57-generic] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Blue Mobile Device Model: WDC WD5000LPVX-22V0TT0 Serial Number: LU WWN Device Id: Firmware Version: User Capacity: 500,107,862,016 bytes [500 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Fri Jan 6 10:13:32 2017 KST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (10260) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 117) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x7035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0027 156 150 021 Pre-fail Always - 1200 4 Start_Stop_Count 0x0032 088 088 000 Old_age Always - 12550 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0 9 Power_On_Hours 0x0032 094 094 000 Old_age Always - 4410 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 641 191 G-Sense_Error_Rate 0x0032 050 050 000 Old_age Always - 50 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 101 193 Load_Cycle_Count 0x0032 192 192 000 Old_age Always - 26203 194 Temperature_Celsius 0x0022 108 089 000 Old_age Always - 35 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
자세한 정보
나는 주로 위에 Power_On_Hour를 확인하기 위해 사용함.
Odroid HC1은 위 옵션으로는 “알수없는 브릿지” 라고 하면서 안나오는데 아래와 같이 옵션을 주면 나온다.
sudo smartctl -x -d sat /dev/sda
답글 남기기